    Abstract: The structure design concept of Chongqing Marriott International Conference Center Building,which is framed tube-core steel structure with panting frame, was stated. The wind load on the building and the method of anti-wind analysis was introduced. The layout of structure, the aseismic measures and the joint structural was described. The occupant comfort of the building was calculated. The results can be reference for the similar structure……

    Keywords: Super high-rise building, framed tube-core steel structure design, wind load, occupant comfort

    一、工程概况

    重庆万豪国际会展大厦地处重庆市闹市区,大厦所处地势北高南低,相差5m.大厦地上69 层(含GF 层),地下5 层,建筑高度303.3m,地下22m,裙房7 层。地下5 层为停车库和设备用房以及商业用房,负2层与城市轻轨的出入口连为一体,地上7 层裙房为商业用房,第7 层采用空中通廊与现有万豪酒店相连,8 至68 层塔楼标准层平面为41×41m,8 至41层为公寓,42 至68 层为办公楼,顶层设置直升机停机坪。在第7 层、第23 层、第41 层、第54 层、顶层设置避难层。地下室和裙房层高4.5m-5m,公寓层高3.7m,办公楼层高3.9m.建筑用地面积9100 ㎡,总建筑面积182893 ㎡,其中地上建筑面积145348 ㎡,地下37545㎡.该大厦周围有10余栋已建或规划的高层或超高层建筑。

    二、 地基与基础

    1.地质情况该场地划分为I 类场地。大厦以巨厚层的中(微)风化泥岩为持力层,根据地勘,泥岩的地基承载力特征值为4.0Mpa,天然抗压强度标准值为12.4Mpa.后经岩质地基平板载荷试验,极限荷载平均值为16.4Mpa,地基承载力特征值为5.2Mpa,该地基是修建高层建筑的理想场地。

    2.基坑及基础设计本工程地下5 层,因地势北高南低。相差5m,具备完全嵌固条件有4 层22m,大厦埋置深度为房屋高度的1/13.8,满足抗倾覆能力。塔楼的柱基础采用扩底桩(墩),塔楼内筒采用平板式筏形基础。我们采用美国ANSYS 公司编制的ANSYS 1 Mechanical 有限元分析软件的SOLID72 单元对塔楼扩底桩(墩)和塔楼筒体筏板及地基进行了三维计算分析,塔楼扩底桩(墩)采用D=4m,扩底5.5m,筏板25.8×25.8×4.5m.为筏板基础配筋提供可参考的数据。

    三、风荷载

    高层超高层建筑中水平风荷载计算是结构抗风设计的关键因素,但对于较高的特别是不规则的超高层建筑,加之建筑物风荷载受周围围建筑影响较大,需对现行规范的风荷载进行核准,为此,该大厦进行了模型风洞测压和气弹试验和三维数值风洞模拟,并与规范取值对比,进行合理的风荷载设计。